Comparative Analysis of the Apical Extrusion of Debris Caused by Different Manual Instrumentation Techniques
The instrumentation stage in endodontic treatment is associated with the extrusion of debris to the periapex, which can lead to postoperative symptoms and delay in apical repair. The present study aimed to perform a comparative analysis of the apical extrusion of debris caused by two different manual instrumentation techniques. Thirty permanent lower central incisors were randomly selected […]
Cyclic and torsional fatigue resistance of thermally treated rotary NiTi instruments with different designs
Introduction: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features. Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was made in […]
Emprego de instrumentos manuais fabricados em NiTi tratados termicamente em dentes com curvaturas acentuadas: relato de caso
O presente relato tem como objetivo descrever o tratamento endodôntico de um dente com acentuada dilaceração radicular, empregando instrumentos manuais fabricados em NiTi tratado termicamente. Paciente do sexo masculino, 14 anos de idade, portador de fenda palatina tratada cirurgicamente, foi encaminhado para tratamento endodôntico do incisivo lateral superior esquerdo (#22) por razões protéticas. Ao exame […]
Mechanical activation with Easy Clean device enhanced organic tissue removal from simulated internal root resorption in a laboratory evaluation
Background: Considering the irregular shape of the root canal, removing inflamed pulp and granulation tissue completely from internal resorption cavities during chemomechanical preparation can be challenging. This study aimed to evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared to mechanical activation with Easy Clean in the removal of organic tissue from simulated areas of internal root […]
Cyclic and torsional fatigue resistance of a new rotary file on a rotary and reciprocating motion
Abstract: This study evaluated the cyclic and torsional fatigue resistance of a new nickeltitanium (Flat File 25.04) instrument on the continuous and reciprocating motion. Sixty instruments of the ProDesign Logic2 25.03 and 25.05 (Easy Equipamentos Odontologicos, Belo Horizonte, Brazil), and MK Flat File 25.04 (n = 20) (MK Life, Porto Alegre, Brazil) were used. For the […]
Apical extrusion of debris produced by the heat treated single-file systems XP-Endo Shaper, Reciproc Blue and ProDesign Logic
Aim: This study evaluated the apical extrusion of debris during root canal preparation produced by the single-file systems XP-Endo Shaper (FKG Dentaire, La Chaux-de- Fonds, Switzerland), Reciproc Blue (VDW GmbH, Munich, Germany), and ProDesign Logic (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil). Methodology: Thirty single straight root canals in mandibular premolar were prepared and randomly assigned to […]
Tratamento endodôntico em dentes com periodontite apical assintomática – Sistema de preparo biomecânico Limas M: Relato de caso
Resumo No cotidiano odontológico é comum os profissionais se depararem com diversos tipos de enfermidades que afetam o s tecidos da região periapical como por exemplo, a periodontite apical assintomática , patologia essa de natureza inflamatória de progressão lenta, que frequentemente comprometem os tecidos periapicais . Essa patologia requer tratamento endodôntico imediato evitando a perda […]
Cyclic and torsional fatigue resistance of three different thermally treated nickel-titanium rotary instruments
Resumo The aim of this study was to evaluate the cyclic fatigue and torsional fatigue resistance of three thermally treated rotary instruments, such as: Logic 2 25.05 (LOG 25.05), Edge Taper Platinum 25.06 (EDT 25.06) and ProTaper Gold 25.08 (PTG 25.08). Methods: A total of 60 rotary instruments of LOG 25.05, EDT 25.06 and PTG […]
O impacto dos instrumentos endodônticos Prodesign M no ensino de graduação
O planejamento educacional da disciplina de Endodontia na graduação deve incorporar novas técnicas para a melhoria do processo formativo. Assim, os instrumentos manuais de níquel titânio ProDesign M (PDM) trouxeram uma proposta inovadora de preparo do canal radicular. Este estudo teve por objetivo avaliar o impacto da introdução dos mesmos no ensino da graduação, por meio da […]
Emprego de instrumentos manuais fabricados em NiTi tratados termicamente em dentes com curvaturas acentuadas: relato de caso
O presente relato tem como objetivo descrever o tratamento endodôntico de um dente com acentuada dilaceração radicular, empregando instrumentos manuais fabricados em NiTi tratado termicamente. Paciente do sexo masculino, 14 anos de idade, portador de fenda palatina tratada cirurgicamente, foi encaminhado para tratamento endodôntico do incisivo lateral superior esquerdo (#22) por razões protéticas. Ao exame […]